This valve assembly, only available in automated version, uses a combination of two main butterfly valves between flanges connected by a channel forming an air space.
This channel is equipped with a leakage microvalve and an optional air space washing microvalve.
When both valves are closed, the venting of the air space indicates a fault on either of the valves.
Diameters
From 1" up to 6"
Working conditions
|
Maximum temperature +248°F |
Minimum temperature 32°F |
|
Working pressure 56 psi to 140 psi |
Vacuum resistance 0.006 gpm |
|
Maximum supply pressure 112 psi |
Minimum supply pressure 63 psi |